Availability: | |
---|---|
Quantity: | |
The 2600N series large screen, scanning type, dual beam spectrophotometer has a user-friendly interface and easy operation, including all the testing functions of a conventional spectrophotometer. The instrument has high precision and low noise, meeting a wide range of application needs such as daily analysis and scientific research.
Features
◆Dual beam optical path can effectively suppress the drift of circuit optical path, suitable for long-term testing
◆Automatic wavelength calibration, automatic dark current and blank correction, automatic switching of light source and filter
◆Spacious sample compartment, capable of accommodating 5-100mm cuvettes, supporting various accessory parts required for testing
◆High quality optical and electronic components ensure high precision, low noise, and low stray light of the instrument
◆ Large screen dot matrix LCD display, digital thin-film key input, user-friendly interface, easy to operate
◆ Long life environmentally friendly flange seat deuterium lamp, no optical debugging required for lamp replacement
◆Real time saving of graphs and data, with the ability to maintain power off, printable, and exportable to PC
◆Sturdy base plate and optical bracket, imported key components, durable and long-lasting
◆Optional PC scanning software makes online operation more convenient and expands data processing and storage capabilities
Function:
◆ Luminescence measurement: transmittance T%, absorbance Abs, energy E
◆ Quantitative testing: concentration content C (coefficient method, standard curve method)
◆ Wavelength scanning (spectral scanning): scanning range, interval, and speed can be set
◆ Time scanning (kinetics): measure the change spectrum and calculate the reaction rate
◆ DNA/protein determination: ratio and concentration are directly displayed, and customizable methods are available
◆ Multi wavelength testing: simultaneously measuring results at multiple arbitrary wavelengths
◆ Other functions: system application, graph data processing, report printing, etc
Specifications:
Model | ZG-EU-2600DN |
Wavelength Range | 190-1100nm |
Spectral Bandwidth | 1.8nm |
Optical System | Dual Beam Optical Path |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤0.2nm |
Wavelength Setting | Automatic wavelength setting, wavelength resolution of 0.1nm |
Photometric Range | 0~200%T, -0.3~3A, 0~9999C, 0~9999F |
Photometric Accuracy | ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T) |
Photometric Repeatability | ≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.15%T (0~100%T) |
Stray Light | ≤0.05%T (220/360nm) |
Scan Speed | Three adjustable speeds: high, medium, and low |
Baseline Flatness | ±0.0015A |
Baseline drift (stability) | ±0.001A/h (500nm,0A) |
Noise | ±0.1%T(0%T line);±0.3%T(100%T line);±0.0005A (500nm) |
Sample Compartment | Accommodate 5-100mm Cuvettes |
Detector | Imported silicon photodiode |
Light source | Imported long-life tungsten and deuterium lamps (without optical debugging) |
Display | 6-inch 320 * 240 dot matrix LCD display |
Keypad | Digital touch film button |
Output Port | USB Port |
Printer | Mini Printer (Optional); PC Printer (Optional) |
PC Software | PC scanning analysis software (optional) |
Power Requirements | AC 90-250V,50/60Hz |
Dimension | 545x468x245mm |
Weight | 20kg |
The 2600N series large screen, scanning type, dual beam spectrophotometer has a user-friendly interface and easy operation, including all the testing functions of a conventional spectrophotometer. The instrument has high precision and low noise, meeting a wide range of application needs such as daily analysis and scientific research.
Features
◆Dual beam optical path can effectively suppress the drift of circuit optical path, suitable for long-term testing
◆Automatic wavelength calibration, automatic dark current and blank correction, automatic switching of light source and filter
◆Spacious sample compartment, capable of accommodating 5-100mm cuvettes, supporting various accessory parts required for testing
◆High quality optical and electronic components ensure high precision, low noise, and low stray light of the instrument
◆ Large screen dot matrix LCD display, digital thin-film key input, user-friendly interface, easy to operate
◆ Long life environmentally friendly flange seat deuterium lamp, no optical debugging required for lamp replacement
◆Real time saving of graphs and data, with the ability to maintain power off, printable, and exportable to PC
◆Sturdy base plate and optical bracket, imported key components, durable and long-lasting
◆Optional PC scanning software makes online operation more convenient and expands data processing and storage capabilities
Function:
◆ Luminescence measurement: transmittance T%, absorbance Abs, energy E
◆ Quantitative testing: concentration content C (coefficient method, standard curve method)
◆ Wavelength scanning (spectral scanning): scanning range, interval, and speed can be set
◆ Time scanning (kinetics): measure the change spectrum and calculate the reaction rate
◆ DNA/protein determination: ratio and concentration are directly displayed, and customizable methods are available
◆ Multi wavelength testing: simultaneously measuring results at multiple arbitrary wavelengths
◆ Other functions: system application, graph data processing, report printing, etc
Specifications:
Model | ZG-EU-2600DN |
Wavelength Range | 190-1100nm |
Spectral Bandwidth | 1.8nm |
Optical System | Dual Beam Optical Path |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤0.2nm |
Wavelength Setting | Automatic wavelength setting, wavelength resolution of 0.1nm |
Photometric Range | 0~200%T, -0.3~3A, 0~9999C, 0~9999F |
Photometric Accuracy | ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T) |
Photometric Repeatability | ≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.15%T (0~100%T) |
Stray Light | ≤0.05%T (220/360nm) |
Scan Speed | Three adjustable speeds: high, medium, and low |
Baseline Flatness | ±0.0015A |
Baseline drift (stability) | ±0.001A/h (500nm,0A) |
Noise | ±0.1%T(0%T line);±0.3%T(100%T line);±0.0005A (500nm) |
Sample Compartment | Accommodate 5-100mm Cuvettes |
Detector | Imported silicon photodiode |
Light source | Imported long-life tungsten and deuterium lamps (without optical debugging) |
Display | 6-inch 320 * 240 dot matrix LCD display |
Keypad | Digital touch film button |
Output Port | USB Port |
Printer | Mini Printer (Optional); PC Printer (Optional) |
PC Software | PC scanning analysis software (optional) |
Power Requirements | AC 90-250V,50/60Hz |
Dimension | 545x468x245mm |