You are here: Home / Products / Spectrophotometer / Ultra Micro Spectrophotometer / ZG-MiUV-1 Ultra Micro Spectrophotometer With Detection Wavelength Range: 200-850nm.

loading

ZG-MiUV-1 Ultra Micro Spectrophotometer With Detection Wavelength Range: 200-850nm.

1.Only a small volume of sample is needed to reduce 
   the required sample consumption, and no dilution 
   is required. Samples ranging from 0.5ul to 2ul can 
   be measured.
2.Detection wavelength range: 200-850nm.
3.Extremely fast detection speed, no need for 
  appointment, can be detected at any time. 
  The measurement of each sample is completed 
   in a very short time for testing.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Function:


Conventional Nucleic Acid Concentration Testing:

1.Includes various nucleic acid samples such as dsDNA, ssDNA, RNA, etc., without the need for sample dilution

2.Automatically calculate and display 260nm and 280nm absorbance, ratio, and sample concentration



Protein Detection:

1.Detect the concentration of purified protein and automatically adjust the optical path without diluting the    

    sample

2.Detection range: 0.05-100mg/mL



Full Spectrum Scanning:

1.Full wavelength scanning from 1200 to 850nm, displaying absorption curve

2.Cell and Microbial Culture Test Substances

3.Detect the absorbance of fluorescent dye labeled proteins


Features

1.Only a small volume of sample is needed to reduce the required sample consumption, and no dilution is    

   required. Samples ranging from 0.5ul to 2ul can be measured.

2.Detection wavelength range: 200-850nm.

3.Extremely fast detection speed, no need for appointment, can be detected at any time. The measurement of  

   each sample is completed in a very short time for testing.

4.Longer optical lifespan, intelligent recognition of user usage, automatically turning off the light source within 5  

   minutes of no operation to extend its lifespan.

5.When the user presses the detection button, it will automatically turn on without user intervention, and the 

   device will automatically recognize it.

6.The graphical software interface is more intuitive, and the results can be directly exported in Excel spreadsheets 

   for easy data viewing and analysis.


Specifications:


Model

ZG-MiUV-1

Sample volume requirements

0.5 - 2uL

Optical path length

0.2mm (high concentration), 1.0mm (normal concentration)

Light source

Pulse flashing xenon lamp

Detector

3864 unit linear CCD array

Wavelength Range

200-850nm

Wavelength accuracy

±1nm

Spectral bandwidth (wavelength resolution)

3nm (FWHM at Hg 546nm)

Photometric range

0.02-75 (equivalent to 10mm)

Photometric accuracy

± 0.003Abs, ± 1% T (0.76A at 350nm)

Range of nucleic acid testing

2ng/uL - 5000ng/uL(dsDNA)

Testing time

5 seconds

External dimensions

W200 x D260 x H150mm

Weight

2.5kg

Sample holder material

Quartz fiber and high hardness aluminum

The power adapter

DC 24V

Power

12-18W

Data and Control Interface

USB port

Software platform

Win XP,Win 7,Win 10


Previous: 
Next: 

Related Products

Testing refractive index nD, average dispersion (nF nC) of liquids or solids and the mass fraction (known as Brix) of dry solids in sugar solution.
Application for detection and analysis in sugar, pharmaceutical, beverage, petroleum, food, chemical industry production, scientific researchand teaching departments.
0
0
1: Support network printing and data statistical retrieval;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: Compliant with 21CFR Part 11 audit trail, pharmacopoeia and electronic signature, compliant with pharmacopoeia FDA functionality;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: Compliant with 21CFR Part 11 audit trail, pharmacopoeia and electronic signature, compliant with pharmacopoeia FDA functionality;
0
0
1.Contains 2-channel liquid adding module, standard 16 stations, optional 20/34/40 station turntable auto sampler.
2.Can drive multiple liquid adding module units, burettes and pipelines should be acid, alkali and corrosion resistant.
3.Imported corrosion-resistant polytetrafluoroethylene rotary valve, PTFE corrosion-resistant burette, high-power stirring table, coil for magnetic stirring.
4.High-precision closed-loop control to ensure accurate titration.
0
0
1: Improve precision and stability;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: The whole machine has passed the TART and CE certification;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Meet 21CFR Part 11, audit tracking, pharmacopoeia and electronic signature;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020, cGMP/GLP requirements and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: LED cold light source replaces traditional sodium and tungsten halogen lamps;
2: Can be used for measuring optical rotation, specific rotation, concentration, and sugar content;
3: Equipped with user management and data printing functions
0
0
1: LED cold light source replaces traditional sodium and tungsten halogen lamps;
2: Can be used for measuring optical rotation, specific rotation, concentration, and sugar content;
3: Equipped with user management and data printing functions
0
0
Adopting visual aiming and manual measurement methods, it is easy to use.
0
0
Adopting photoelectric detection and automatic servo mechanism control, digital display reading, capable of measuring dark samples; It can also measure sugar content and is equipped with an RS232 interface, which can transmit data to a PC.
0
0
1.The control unit adopts a 16 bit microprocessor chip, which makes the computer faster and has good real-time performance.
2.Digital temperature control regulation has been achieved, allowing for arbitrary setting of starting temperature and selection of different linear heating rates.
3.Enhanced anti-interference capability through digital filtering technology.
4.It can automatically record the initial and final melting temperatures.
0
0
1: Test mode: melting point, boiling point, sliding point;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Comply with 21CFR Part 11, audit tracking, pharmacopoeia and electronic signature;
0
0

Request A Free Quote

We are always ready to assist you with your inquiries. You can contact us via email, and we will make every effort to help resolve your issues and meet your needs.
Contact Us
Shanghai Zhuoguang Instrument Technology Co., Ltd. focuses on the scientific instrument industry, manufacturing high-quality instruments and providing perfect services.

Quick Links

Contact Us
 +86-18116419193
 +8618116419193
 +86-21-59501820
 Room 308B, Building1, Tongxing Creative Industrial Park, Caoan Road 4260, Jiading District, Shanghai, 201804, China.
Leave a Message
Contact Us
Copyright © 2025 Shanghai Zhuoguang Instrument Technology Co., Ltd.  All Rights Reserved. Sitemap | Privacy Policy