Availability: | |
---|---|
Quantity: | |
Function:
Conventional Nucleic Acid Concentration Testing:
1.Includes various nucleic acid samples such as dsDNA, ssDNA, RNA, etc., without the need for sample dilution
2.Automatically calculate and display 260nm and 280nm absorbance, ratio, and sample concentration
Protein Detection:
1.Detect the concentration of purified protein and automatically adjust the optical path without diluting the
sample
2.Detection range: 0.05-100mg/mL
Full Spectrum Scanning:
1.Full wavelength scanning from 1200 to 850nm, displaying absorption curve
2.Cell and Microbial Culture Test Substances
3.Detect the absorbance of fluorescent dye labeled proteins
Features
1.Only a small volume of sample is needed to reduce the required sample consumption, and no dilution is
required. Samples ranging from 0.5ul to 2ul can be measured.
2.Detection wavelength range: 200-850nm.
3.Extremely fast detection speed, no need for appointment, can be detected at any time. The measurement of
each sample is completed in a very short time for testing.
4.Longer optical lifespan, intelligent recognition of user usage, automatically turning off the light source within 5
minutes of no operation to extend its lifespan.
5.When the user presses the detection button, it will automatically turn on without user intervention, and the
device will automatically recognize it.
6.The graphical software interface is more intuitive, and the results can be directly exported in Excel spreadsheets
for easy data viewing and analysis.
Specifications:
Model | ZG-MiUV-1 |
Sample volume requirements | 0.5 - 2uL |
Optical path length | 0.2mm (high concentration), 1.0mm (normal concentration) |
Light source | Pulse flashing xenon lamp |
Detector | 3864 unit linear CCD array |
Wavelength Range | 200-850nm |
Wavelength accuracy | ±1nm |
Spectral bandwidth (wavelength resolution) | 3nm (FWHM at Hg 546nm) |
Photometric range | 0.02-75 (equivalent to 10mm) |
Photometric accuracy | ± 0.003Abs, ± 1% T (0.76A at 350nm) |
Range of nucleic acid testing | 2ng/uL - 5000ng/uL(dsDNA) |
Testing time | 5 seconds |
External dimensions | W200 x D260 x H150mm |
Weight | 2.5kg |
Sample holder material | Quartz fiber and high hardness aluminum |
The power adapter | DC 24V |
Power | 12-18W |
Data and Control Interface | USB port |
Software platform | Win XP,Win 7,Win 10 |
Function:
Conventional Nucleic Acid Concentration Testing:
1.Includes various nucleic acid samples such as dsDNA, ssDNA, RNA, etc., without the need for sample dilution
2.Automatically calculate and display 260nm and 280nm absorbance, ratio, and sample concentration
Protein Detection:
1.Detect the concentration of purified protein and automatically adjust the optical path without diluting the
sample
2.Detection range: 0.05-100mg/mL
Full Spectrum Scanning:
1.Full wavelength scanning from 1200 to 850nm, displaying absorption curve
2.Cell and Microbial Culture Test Substances
3.Detect the absorbance of fluorescent dye labeled proteins
Features
1.Only a small volume of sample is needed to reduce the required sample consumption, and no dilution is
required. Samples ranging from 0.5ul to 2ul can be measured.
2.Detection wavelength range: 200-850nm.
3.Extremely fast detection speed, no need for appointment, can be detected at any time. The measurement of
each sample is completed in a very short time for testing.
4.Longer optical lifespan, intelligent recognition of user usage, automatically turning off the light source within 5
minutes of no operation to extend its lifespan.
5.When the user presses the detection button, it will automatically turn on without user intervention, and the
device will automatically recognize it.
6.The graphical software interface is more intuitive, and the results can be directly exported in Excel spreadsheets
for easy data viewing and analysis.
Specifications:
Model | ZG-MiUV-1 |
Sample volume requirements | 0.5 - 2uL |
Optical path length | 0.2mm (high concentration), 1.0mm (normal concentration) |
Light source | Pulse flashing xenon lamp |
Detector | 3864 unit linear CCD array |
Wavelength Range | 200-850nm |
Wavelength accuracy | ±1nm |
Spectral bandwidth (wavelength resolution) | 3nm (FWHM at Hg 546nm) |
Photometric range | 0.02-75 (equivalent to 10mm) |
Photometric accuracy | ± 0.003Abs, ± 1% T (0.76A at 350nm) |
Range of nucleic acid testing | 2ng/uL - 5000ng/uL(dsDNA) |
Testing time | 5 seconds |
External dimensions | W200 x D260 x H150mm |
Weight | 2.5kg |
Sample holder material | Quartz fiber and high hardness aluminum |
The power adapter | DC 24V |
Power | 12-18W |
Data and Control Interface | USB port |
Software platform | Win XP,Win 7,Win 10 |