ZG-EU-2800D UV-VIS Spectrophotometer, Double Beam, Spectral Bandwidth 1.8nm Large Screen Scanning

◆ Luminescence measurement: transmittance T%, 
   absorbance Abs, energy E
◆ Quantitative testing: concentration content C 
   (coefficient method, standard curve method)
◆ Wavelength scanning (spectral scanning): 
   scanning range, interval, and speed can be set
◆Time scanning (kinetics): measure the change 
  spectrum and calculate the reaction rate
◆ DNA/protein determination: ratio and concentration 
   are directly displayed, and customizable methods are 
   available
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

2800D series spectrophotometer are advanced double beam optical system. Double beam optical structure can inhibit the drift, Suitable for long time test.The 2800D series spectrophotometer has advanced functions such as quantitative measurement, wavelength scanning, time scanning, multi wavelength testing, DNA protein testing, etc. It has the characteristics of high precision, high resolution, low noise, and low stray light, and is particularly suitable for fields such as scientific research, pharmaceutical inspection, life sciences, environmental monitoring, metallurgy and chemical engineering.


Features

◆ Dual beam proportional monitoring optical path, low drift and high stability, suitable for long-term testing

◆ Push pull sample cover design, can be opened and closed with both hands, easy to operate

◆ Spacious sample compartment, capable of accommodating 5-100mm cuvettes, supporting various accessory 

   parts required for testing

◆ High quality optical and electronic components ensure high precision and low stray light of the instrument

◆ Large screen dot matrix LCD, clear display of graph data, user-friendly interface, easy operation

◆ Smaller spectral bandwidth, higher resolution, fully meets pharmacopoeia requirements, and has a wider range 

   of applications

◆ Long life environmentally friendly flange seat deuterium lamp, no optical debugging required for lamp 

   replacement

◆ Real time saving of graphs and data, with the ability to maintain power off, printable, and exportable to PC

◆ Sturdy base plate and optical bracket, imported key components, durable and long-lasting

◆ Standard PC scanning software, more convenient online operation, and expanded data processing and storage 

   capabilities


Function:

◆ Luminescence measurement: transmittance T%, absorbance Abs, energy E

◆ Quantitative testing: concentration content C (coefficient method, standard curve method)

◆ Wavelength scanning (spectral scanning): scanning range, interval, and speed can be set

◆ Time scanning (kinetics): measure the change spectrum and calculate the reaction rate

◆ DNA/protein determination: ratio and concentration are directly displayed, and customizable methods are 

   available

◆ Multi wavelength testing: simultaneously measuring results at multiple arbitrary wavelengths

◆ Other functions: system application, graph data processing, report printing, etc


Specifications:


Model

ZG-EU-2800D

ZG-EU-2800DA

ZG-EU-2800DS

Wavelength Range

190-1100nm

Spectral Bandwidth

1.8nm

1.0nm

0.5/1/1.5/2/4/5nm

Optical System

Dual beam optical path, holographic diffraction grating

Wavelength Accuracy

±0.1nm(656.1nm);±0.3nm(the entire range)

Wavelength Repeatability

≤0.1nm

Wavelength Setting

Automatic wavelength setting, wavelength resolution of 0.1nm

Photometric Range

0~200%T, -4~4A, 0~9999C, 0~9999F

Photometric Accuracy

±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T)

Photometric Repeatability

≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.1%T (0~100%T)

Stray Light

≤0.03%T (220/360nm)

Scan Speed

Three adjustable speeds: high, medium, and low

Baseline Flatness

±0.001A

Baseline drift (stability)

≤0.0008A/h (500nm,0A)

Noise

±0.1%T(0%T line); ±0.3%T(100%T line); ±0.0004A (500nm)

Sample Compartment

Accommodate 5-100mm Cuvettes

Detector

Imported silicon photodiode

Light source

Imported long-life tungsten and deuterium lamps (without optical debugging)

Display

6-inch 320x240 dot matrix LCD

Keypad

Digital touch film button

Output Port

USB Port

Printer

Mini Printer (Optional); PC Printer (Optional)

PC Software

PC scanning analysis software (standard)

Power Requirements

AC 90-250V,50/60Hz

Dimension

635x515x255mm

Weight

26kg

26kg

28kg


Previous: 
Next: 

Related Products

Testing refractive index nD, average dispersion (nF nC) of liquids or solids and the mass fraction (known as Brix) of dry solids in sugar solution.
Application for detection and analysis in sugar, pharmaceutical, beverage, petroleum, food, chemical industry production, scientific researchand teaching departments.
0
0
1: Support network printing and data statistical retrieval;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: Compliant with 21CFR Part 11 audit trail, pharmacopoeia and electronic signature, compliant with pharmacopoeia FDA functionality;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: Compliant with 21CFR Part 11 audit trail, pharmacopoeia and electronic signature, compliant with pharmacopoeia FDA functionality;
0
0
1.Contains 2-channel liquid adding module, standard 16 stations, optional 20/34/40 station turntable auto sampler.
2.Can drive multiple liquid adding module units, burettes and pipelines should be acid, alkali and corrosion resistant.
3.Imported corrosion-resistant polytetrafluoroethylene rotary valve, PTFE corrosion-resistant burette, high-power stirring table, coil for magnetic stirring.
4.High-precision closed-loop control to ensure accurate titration.
0
0
1: Improve precision and stability;
2: LED cold light source instead of traditional sodium lamp and halogen tungsten lamp;
3: 7-inch touch color screen, humanized operation interface;
4: The whole machine has passed the TART and CE certification;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Meet 21CFR Part 11, audit tracking, pharmacopoeia and electronic signature;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020, cGMP/GLP requirements and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: Built-in Peltier temperature control, improve accuracy and stability;
2: LED cold light source instead of the traditional sodium lamp and halogen tungsten lamp;
3: Compliance with 21CFR Part 11 audit tracking, comply with Pharmacopoeia 2020 and electronic signature;
0
0
1: LED cold light source replaces traditional sodium and tungsten halogen lamps;
2: Can be used for measuring optical rotation, specific rotation, concentration, and sugar content;
3: Equipped with user management and data printing functions
0
0
1: LED cold light source replaces traditional sodium and tungsten halogen lamps;
2: Can be used for measuring optical rotation, specific rotation, concentration, and sugar content;
3: Equipped with user management and data printing functions
0
0
Adopting visual aiming and manual measurement methods, it is easy to use.
0
0
Adopting photoelectric detection and automatic servo mechanism control, digital display reading, capable of measuring dark samples; It can also measure sugar content and is equipped with an RS232 interface, which can transmit data to a PC.
0
0
1.The control unit adopts a 16 bit microprocessor chip, which makes the computer faster and has good real-time performance.
2.Digital temperature control regulation has been achieved, allowing for arbitrary setting of starting temperature and selection of different linear heating rates.
3.Enhanced anti-interference capability through digital filtering technology.
4.It can automatically record the initial and final melting temperatures.
0
0
1: Test mode: melting point, boiling point, sliding point;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Automatic recording of melting process, initial melting, final melting;
0
0
1: Automatic integration to realize one-button measurement function;
2: Treat 4 samples at a time;
3: HD video instead of the traditional microscope, high visual inspection;
4: Comply with 21CFR Part 11, audit tracking, pharmacopoeia and electronic signature;
0
0

Request A Free Quote

We are always ready to assist you with your inquiries. You can contact us via email, and we will make every effort to help resolve your issues and meet your needs.
Contact Us
Shanghai Zhuoguang Instrument Technology Co., Ltd. focuses on the scientific instrument industry, manufacturing high-quality instruments and providing perfect services.

Quick Links

Contact Us
 +86 18964419749
 +86 18964419749
 +86-21-59501820
 Room 308B, Building1, Tongxing Creative Industrial Park, Caoan Road 4260, Jiading District, Shanghai, 201804, China.
Leave a Message
Contact Us
Copyright © 2025 Shanghai Zhuoguang Instrument Technology Co., Ltd.  All Rights Reserved. Sitemap | Privacy Policy