Availability: | |
---|---|
Quantity: | |
The 2600 series spectrophotometer is practical and easy to operate. Equipped with a dot matrix LCD display, it can perform photometric measurement and quantitative testing, and display standard curve spectra directly. Optional PC scanning analysis software is available, making online operation more convenient, and adding functions such as wavelength scanning, time scanning, data processing, and report printing, expanding data storage capacity. Widely used in teaching research and daily analysis.
Features
◆ Dual beam optical path can effectively suppress the drift of circuit optical path, suitable for long-term testing
◆ Automatic wavelength calibration, automatic dark current and blank correction, automatic switching of light
source and filter
◆ Spacious sample compartment, capable of accommodating 5-100mm cuvettes, supporting various accessory
parts required for testing
◆ High quality optical and electronic components ensure high precision and low stray light of the instrument
◆ Dot matrix LCD display, touch film buttons, user-friendly interface, easy to operate
◆ Long life environmentally friendly flange seat deuterium lamp, no optical debugging required for lamp
replacement
◆ Real time saving of graphs and data, with the ability to maintain power off, printable, and exportable to PC
◆ Sturdy base plate and optical bracket, imported key components, durable and long-lasting
◆ Optional PC scanning analysis software, more convenient online operation, expands data processing and storage
capabilities
Function:
◆ Luminescence measurement: transmittance T%, absorbance Abs, energy E
◆ Quantitative testing: concentration content C (coefficient method, standard curve method)
◆ Wavelength scanning (spectral scanning): PC online function
◆ Time scanning (dynamics): PC online function
◆ DNA/protein determination: PC online function
◆ Multi wavelength testing: PC online function
◆ Other functions: system applications, data processing, report printing, etc
Specifications:
Model | ZG-EV-2600 | ZG-EU-2600 | ZG-EU-2600D | |
Wavelength Range | 320-1100nm | 190-1100nm | 190-1100nm | |
Spectral Bandwidth | 1.8nm (4.0nm Optional) | |||
Optical System | Single beam optical path | Single beam optical path | Dual beam optical path | |
Wavelength Accuracy | ±0.5nm | |||
Wavelength Repeatability | ≤0.2nm | |||
Wavelength Setting | Automatic wavelength setting, wavelength resolution of 0.1nm | |||
Photometric Range | 0~200%T, -0.3~3A, 0~9999C, 0~9999F | |||
Photometric Accuracy | ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T) | |||
Photometric Repeatability | ≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.15%T (0~100%T) | |||
Stray Light | ≤0.05%T(220nm,NaI; 340nm,NaNo2) | |||
Scan Speed | Three adjustable speeds: high, medium, and low | |||
Baseline Flatness | ±0.002A | |||
Baseline drift (stability) | ≤0.001A/h (500nm,0A) | |||
Noise | ±0.1%T(0%T line);±0.3%T(100%T line);±0.001A (500nm) | |||
Sample Compartment | Accommodate 5-100mm Cuvettes | |||
Detector | Imported silicon photodiode | |||
Light source | Imported long-life tungsten and deuterium lamps (without optical debugging) | |||
Display | 3-inch 128 * 64 dot matrix LCD display | |||
Keypad | Digital touch film button | |||
Output Port | USB Port | |||
Printer | Mini Printer (Optional); PC Printer (Optional) | |||
PC Software | PC quantitative software (optional); PC scanning software (optional) | |||
Power Requirements | AC 90-250V,50/60Hz | |||
Dimension | 490x390x280mm | |||
Weight | 16kg | 18kg | 18kg |
The 2600 series spectrophotometer is practical and easy to operate. Equipped with a dot matrix LCD display, it can perform photometric measurement and quantitative testing, and display standard curve spectra directly. Optional PC scanning analysis software is available, making online operation more convenient, and adding functions such as wavelength scanning, time scanning, data processing, and report printing, expanding data storage capacity. Widely used in teaching research and daily analysis.
Features
◆ Dual beam optical path can effectively suppress the drift of circuit optical path, suitable for long-term testing
◆ Automatic wavelength calibration, automatic dark current and blank correction, automatic switching of light
source and filter
◆ Spacious sample compartment, capable of accommodating 5-100mm cuvettes, supporting various accessory
parts required for testing
◆ High quality optical and electronic components ensure high precision and low stray light of the instrument
◆ Dot matrix LCD display, touch film buttons, user-friendly interface, easy to operate
◆ Long life environmentally friendly flange seat deuterium lamp, no optical debugging required for lamp
replacement
◆ Real time saving of graphs and data, with the ability to maintain power off, printable, and exportable to PC
◆ Sturdy base plate and optical bracket, imported key components, durable and long-lasting
◆ Optional PC scanning analysis software, more convenient online operation, expands data processing and storage
capabilities
Function:
◆ Luminescence measurement: transmittance T%, absorbance Abs, energy E
◆ Quantitative testing: concentration content C (coefficient method, standard curve method)
◆ Wavelength scanning (spectral scanning): PC online function
◆ Time scanning (dynamics): PC online function
◆ DNA/protein determination: PC online function
◆ Multi wavelength testing: PC online function
◆ Other functions: system applications, data processing, report printing, etc
Specifications:
Model | ZG-EV-2600 | ZG-EU-2600 | ZG-EU-2600D | |
Wavelength Range | 320-1100nm | 190-1100nm | 190-1100nm | |
Spectral Bandwidth | 1.8nm (4.0nm Optional) | |||
Optical System | Single beam optical path | Single beam optical path | Dual beam optical path | |
Wavelength Accuracy | ±0.5nm | |||
Wavelength Repeatability | ≤0.2nm | |||
Wavelength Setting | Automatic wavelength setting, wavelength resolution of 0.1nm | |||
Photometric Range | 0~200%T, -0.3~3A, 0~9999C, 0~9999F | |||
Photometric Accuracy | ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T) | |||
Photometric Repeatability | ≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.15%T (0~100%T) | |||
Stray Light | ≤0.05%T(220nm,NaI; 340nm,NaNo2) | |||
Scan Speed | Three adjustable speeds: high, medium, and low | |||
Baseline Flatness | ±0.002A | |||
Baseline drift (stability) | ≤0.001A/h (500nm,0A) | |||
Noise | ±0.1%T(0%T line);±0.3%T(100%T line);±0.001A (500nm) | |||
Sample Compartment | Accommodate 5-100mm Cuvettes | |||
Detector | Imported silicon photodiode | |||
Light source | Imported long-life tungsten and deuterium lamps (without optical debugging) | |||
Display | 3-inch 128 * 64 dot matrix LCD display | |||
Keypad | Digital touch film button | |||
Output Port | USB Port | |||
Printer | Mini Printer (Optional); PC Printer (Optional) | |||
PC Software | PC quantitative software (optional); PC scanning software (optional) | |||
Power Requirements | AC 90-250V,50/60Hz | |||
Dimension | 490x390x280mm | |||
Weight | 16kg | 18kg | 18kg |